ZSFC150 Fire Protection system Dry Alarm Valve

ZSFC150 Fire Alarm Valve, usually the pipe network is filled with compressed air or nitrogen, so it is suitable for places where the ambient temperature is lower than 4℃ or higher than 70℃.
  • Brand:

    GBOCO or Guangbo
  • Item no.:

    150 Dry Alarm Valve
  • Payment:

    T/T, Chinese Agent Transfer RMB, Cash Payment
  • Product origin:

    Fujian, China
  • Color:

    Usualy is Red
  • Goods stock:

    50
  • Shipping port:

    Xiamen-Fujian, Or Other Seaport in China
  • Lead Time:

    7-15 days
  • Product Details

The characteristics of the dry alarm valve system are:

1. There is no water in the pipeline of the alarm valve, so it is not afraid of freezing or high temperature;

2. Due to the exhaust process after the nozzle moves, the fire extinguishing speed is slower than that of the wet system;

3. Because of the inflatable equipment, the construction investment is relatively high, and the usual management is also more complicated and demanding;

4. It is suitable for places where the environment is below 4 degrees Celsius and above 70 degrees Celsius, but the wet automatic sprinkler system cannot be used, such as cold and boiler rooms.


Dry alarm valve is an important part of dry automatic sprinkler system. It controls the valve and is used to put on or cut off the water supply and output alarm water flow.  Usually in the normally closed state, fire automatically open.  

The main valve is composed of valve body, inner seat ring, outer seat ring, disc assembly, valve cover and other parts.  The disc assembly and inner and outer seat divide the main valve into three parts: upper chamber, middle chamber and lower chamber.  The upper chamber is the valve chamber of the department above the closed valve disc, which is connected to the system pipe network and filled with pressure gas;  The middle cavity is closed valve disc and inner and outer seat ring surrounded by annular space, because the valve disc is closed outer seat ring and inner seat ring at the same time, so the middle cavity is not connected with the upper cavity, and not connected with the lower cavity, and through the hole and the atmosphere;  The lower chamber is the valve chamber below the closed valve disc, connected with the water supply side pipeline, and filled with pressure water.  

When the disc is closed, the action area of the lower chamber pressure water on the disc is smaller than that of the upper chamber pressure gas on the disc, and the ratio of the two is the differential ratio.  For example, the differential ratio of dry alarm valve is about 1:5.  It can be considered that the thrust generated by water pressure can be overcome by charging pressure of 1/4 water pressure and the valve disc can be closed.  According to the differential ratio, compare different water supply pressures.  

Disc assembly is an important part of the main valve of dry alarm valve, which is composed of disc body, disc gasket, pressure plate, clasp, tension spring and other parts.  

Disc gasket, is a key part of the assembly, because it is simultaneously external seat ring and inner seat ring seal, must ensure that the inner and outer ring surface is smooth, no mottled, scratch, dirt and other defects affecting the sealing performance, and must ensure that the combined with the inner and outer seat ring surface smooth, smooth.  When the sealing gasket is replaced due to damage, it must be replaced with the corresponding type of sealing gasket to prevent sealing problems.  

The function of the claw and the tension spring is to automatically reset the textile valve after opening. The special structure ensures that the claw can only rotate counterclockwise at a certain Angle.  When the disc is opened under the action of water pressure, the front end of the claw (upper) touches the reset axis of the external reset structure, and the claw rotates counterclockwise to avoid the reset axis, and does not impede the movement of the disc;  When the disc falls back due to its own weight, the front end of the claw (lower part) will also touch the reset shaft, because the claw can not turn clockwise, so the reset shaft will prevent the disc from falling back in succession to prevent the disc from automatic reset.  

Plates and bolts are used to secure gaskets and disc bodies.  When replacing the gasket, it is necessary to ensure that the pressure plate is smooth, not to damage the deformation, and not to stick dirt, and must ensure that the gasket and the valve body connection surface is smooth and clean.  

For more information about dry alarm valve, please contact the customer service of Fujian Guangbo Fire Equipment Co., LTD.  



Model number is bellow:

ZSFC100 dry alarm valve

ZSFC150 dry alarm valve

ZSFC200 dry alarm valve











Hello, Customers, It is my pleasure to show you our website, If You Add Bellow Contacts, We Could Talk More Easily, if have any questions about fire protection products, please contact us soon! Thanks!

Our company provides technical support for who use our Firefighting products. Please contact the technical department of our company, if any problem in the procurement, installation, use and maintenance process, our technical staff will immediately provide related technical support.







Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
Wet Alarm Valve
ZSFZ100 DN100 Wet Alarm Valve
Wet Fire Fighting System Wet Alarm Valve, model is ZSFZ100 (DN100).
Wet Alarm Valve
ZSFZ150 DN150 Wet Alarm Valve
Wet Fire Fighting System Wet Alarm Valve, model is ZSFZ150 (DN150).
Wet Alarm Valve
ZSFZ200 DN200 Wet Alarm Valve
Wet Fire Fighting System Wet Alarm Valve, model is ZSFZ200 (DN200).
Deluge Alarm Valve
ZSFM Series Deluge Alarm Valve
ZSFM Series Deluge Alarm Valve, has ZSFM100, ZSFM150, ZSFM200, ZSFM250
Saddle Type Water Flow Indicator
Saddle Zsjz Water Flow Indicator Series for Fire Protection Fighting
Saddle Type Water Flow Indicator, has DN50/65, DN80/100, DN125/150, DN200.
Dry Alarm Valve
200 Dry Alarm Valve Fire Protection system
ZSFC200 Dry Alarm Valve, usually the pipe network is filled with compressed air or nitrogen, so it is suitable for places where the ambient temperature is lower than 4℃ or higher than 70℃.
Pre-action Automatic Fire Sprinkler System
DN250 Pre-action Automatic Fire Sprinkler System
This page is about DN250 details information. Pre-action Automatic Fire Sprinkler System, has ZSFY100, ZSFY150, ZSFY200, ZSFY250. 
Pre-action Automatic Fire Sprinkler System
Pre-action Automatic Fire Sprinkler System
This page is about DN250 details information. Pre-action Automatic Fire Sprinkler System, has ZSFY100, ZSFY150, ZSFY200, ZSFY250.
Get in touch
Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact